| UVW
SERIES ERROR CODES
|
||||
| Main Code 02 | ||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
058 |
It is detected that the current of the S reel motor is not normal.
|
AUTO OFF
|
EJECT |
Display until pressing any button or until inserting a cassette tape
again.
|
|
078
|
It is detected that the current of the T reel motor is not normal.
|
|||
|
154
|
The S reel FG cannot be detected by FG check when inserting a cassette
tape.
|
Removes cassette tape automatically.
|
-
|
|
|
174
|
The T reel FG cannot be detected by FG check when inserting a cassette
tape.
|
|||
|
194
|
Neither S reel FG nor T reel FG can be detected by FG check when
inserting a cassette tape.
|
|||
|
255
|
The S reel FG is detected in threading.
|
AUTO OFF
|
EJECT |
|
|
274
|
The T reel FG cannot be detected in threading.
|
|||
|
355
|
The S reel FG is detected in STOP or STILL mode.
|
|||
|
375
|
The T reel FG is detected in STOP or STILL mode.
|
|||
|
395
|
The S reel FG and T reel FG are detected in STOP or STILL mode.
|
|||
|
402
|
It is detected that the tape does not run at the specified speed in F.
FWD or REW mode.
|
STOP
|
Error is remedied, then the unit operates normally.
|
Displays until pressing any button.
|
|
403
|
The Slack of the tape is detected in F. FWD or REW mode.
|
AUTO OFF
|
EJECT |
Display until pressing any button or until inserting a cassette tape
again.
|
|
454
|
The S reel FG cannot be detected in F. FWD or REW mode.
|
|||
|
474
|
The T reel FG cannot be detected in F. FWD or REW mode.
|
|||
|
494
|
Neither S reel FG nor T reel FG can be detected in F. FWD or REW mode.
|
|||
|
496
|
It is detected that the rotations of S and T reel are not normal in F.
FWD or REW mode.
|
|||
|
503
|
The slack of the tape is detected in SEARCH mode.
|
|||
|
554
|
The S reel FG cannot be detected in SEARCH mode.
|
|||
|
574
|
The T reel FG cannot be detected in SEARCH mode.
|
|||
|
594
|
Neither S reel FG nor T reel FG can be detected in SEARCH mode.
|
AUTO OFF
|
EJECT |
Display until pressing any button or until inserting a cassette tape
again.
|
|
596
|
It is detected that the rotations of S and T reel are not normal in
SEARCH mode.
|
|||
|
603
|
The slack of the tape is detected in PLAY or REC mode.
|
|||
|
654
|
The S reel FG cannot be detected in PLAY or REC mode.
|
|||
|
674
|
The T reel FG cannot be detected in PLAY or REC mode.
|
|||
|
694
|
Neither S reel FG not T reel FG can be detected in PLAY or REC.
|
|||
|
696
|
It is detected that the rotations of S reel and T reel are not normal
in PLAY or REC.
|
|||
|
803
|
The slack of the tape is detected when unthreading.
|
|||
|
855
|
The S reel FG is detected when unthreading.
|
|||
|
874
|
The T reel FG cannot be detected when unthreading.
|
|||
|
A55
|
The S reel FG is detected during removal of a cassette tape.
|
Until the error is remedied, inhibits inserting a cassette tape.
|
||
|
A75
|
The T reel FG is detected during removal of a cassette tape.
|
|||
|
A95
|
The S reel FG and T reel FG are detected during removal of cassette
tape.
|
|||
| Main Code 09 | ||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
028
|
It is detected that the current of the threading motor is not normal.
|
AUTO OFF
|
EJECT |
Display until pressing any button or until inserting a cassette tape
again.
|
|
209
|
When detects full top or end of a tape in the threading state and then
performs SHORT FF/SHORT REW, top or end is not released.
|
Removes cassette tape automatically.
|
-
|
|
|
221
|
Threading is not completed within the specified time.
|
AUTO OFF
|
EJECT
(Emergency EJECT) |
|
|
821
|
Unthreading is not completed within the specified time.
|
|||
| Main Code 2X: Mechanical control system problem | ||||
| Main Code 20 | ||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
018
|
It is detected that the current of the cassette up/down motor is not normal. |
AUTO OFF
|
EJECT (Emergency EJECT) |
Display until pressing any button or until inserting a cassette tape
again.
|
|
111
|
The operation of cassette down is not completed within the specified time. | Removes cassette tape automatically. |
-
|
|
|
911
|
The operation of cassette up is not completed within the specified time;. |
AUTO OFF
|
Inhibits all modes.
|
|
| Main Code 21 | ||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
0C8
|
It is detected that the current of the reel position motor is not normal. |
AUTO OFF
|
EJECT (Emergency EJECT) |
Display until pressing any button or until inserting a cassette tape
again.
|
|
1C1
|
The driving of the reel position is not completed within the specified time. | Removes cassette tape automatically. |
-
|
|
|
Main Code 3X : Sensors problem |
||||
|
The sub code of the main code 3X is 000. |
||||
|
Main Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
30
|
Tape-top and tape-end are detected at the same time. |
STOP
|
PLAY, EJECT
|
Displays until an error is clear up.
|
|
31
|
Tape-top is not released. |
STOP
|
PLAY, FF, EJECT
|
|
|
32
|
Tape-top is not released. |
STOP
|
PLAY, REW, EJECT
|
|
|
33
|
The reel position sensor detects the L position and S Position at the same time. | Inhibits inserting a cassette tape. | ||
| Main code 9X : Communication and interface systems problem | ||
|
Main Code
|
Sub Code
|
Detection
|
|
91
|
125
|
Interface problem detected between system control and keyboard. |
|
138
|
Problem detected in the hours meter data EEPROM. | |
|
145
|
Initialization problem detected between system control and servo. | |
|
165
|
Interface problem detected between system control and TBC. | |
|
436
|
Problem detected in servo adjustment data EEPROM. | |
|
455
|
Interface problem detected between main servo and sub servo. | |
|
92
|
000
|
1/2 VD signal at system control input cannot be detected. |
|
93
|
000
|
Servo reference sync signal cannot be detected. |
|
94
|
000
|
Servo input sync signal cannot be detected. |
|
Main code 06
|
||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
6A7
|
It is detected that the tape tension is not normal in PLAY or REC mode. |
Continues operating in the mode in which the problem is detected. When
enters other than PLAY or REC mode, AUTO OFF.
|
The error is remedied, then the unit operates normally. In PLAY or REC mode: Continues operating. In other than PLAY or REC mode: STOP. then EJECT. (Emergency EJECT) |
Displays until the error is remedied and pressing any button.
|
| Main Code 07 | ||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
042
|
It is detected that the speed of the capstan is not normal. |
STOP
|
The error is remedied, then the unit operates normally.
|
Displays until pressing any button.
|
|
144
|
The capstan FG cannot be detected by FG check when inserting a cassette tape. |
Removes cassette tape automatically.
|
-
|
Display until inserting a cassette tape again.
|
| Main Code 08 | ||||
|
Sub Code
|
Detection
|
Operation after detection
|
Valid mode
|
Display
|
|
03A
|
It is detected that the speed of the drum is not normal. ERROR DRUM SPEED ERROR HAS BEEN DETECTED WAIT UNTIL THIS INDICATION GOES OFF. |
RETRY (Once unthreading, then threading again.) |
EJECT
|
Displays until the error is remedied. |
|
032
|
The drum speed problem is not remedied. |
AUTO OFF
|
EJECT
|
Displays until inserting a cassette tape again. |